Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove spark lead and earth wire from electrode
Measurement:
Measure the resistance across the disconnected leads.
There are two types of ignition lead that may be fitted on this appliance.
If a red ignition cap lead is fitted expect
approximately 350 Ohms between the leads.
If black ignition cap lead is fitted expect
approximately 1.35 kOhms between the leads.
There are two types of ignition lead that may be fitted on this appliance.
If a red ignition cap lead is fitted expect
approximately 350 Ohms between the leads.
If black ignition cap lead is fitted expect
approximately 1.35 kOhms between the leads.

Isolate as per TOPs P4
and refit as necessary