Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector from spark generator
Remove connector X2 from the PCB
Remove connector X2 from the PCB
Measurement:
Measure the resistance of the outer two brown and blue wires on connector X2 to the corresponding pins inside the spark generator connector as shown.
Expect continuity / zero resistance on both of the wires in the harness.
Are the resistances measured as expected?
Expect continuity / zero resistance on both of the wires in the harness.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary