Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Remove fan driver PCB from the fan assembly & make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the 4 minute pump purge to complete.
Approximately 10 seconds after DHW demand, measure for AC voltage
between connection C1 on the PCB and a suitable Earth.
Voltage measured will be seen to fluctuate on the multimeter.

The image above is only an example of what a multimeter fluctuating looks like, your multimeter may display different readings.
Does the voltage fluctuate?
Note:
Appliance may enter lockout during this test, reset as required until test complete.