Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove air intake
Remove electrical connector to parameter unit

Measurement:

Measure the resistance between pins 10, 11, 12 and 13 on
connector X5 on the PCB to the disconnected parameter
unit connector, as per the table below;
Pin on connector X5Parameter unit connector
104
11 1
123
132

Expect continuity / zero resistance on each wire.
Also visually inspect the condition of the harness.
Note.
Place the probe in the small holes on the PCB.