Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance if required (press and hold the reset button until the chimney
sweep button LED flashes rapidly, then release the reset button)
Allow the 4 minute pump purge to complete.
During the ignition sequence can the burner be heard to ignite?
Note.
1. The burner may only ignite for a few seconds, then ignition starts again.
2. The appliance will go to ignition lockout (3 red flashes) after 5 attempts to ignite,
reset appliance as required.
sweep button LED flashes rapidly, then release the reset button)
Allow the 4 minute pump purge to complete.
During the ignition sequence can the burner be heard to ignite?
Note.
1. The burner may only ignite for a few seconds, then ignition starts again.
2. The appliance will go to ignition lockout (3 red flashes) after 5 attempts to ignite,
reset appliance as required.