Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Click here for important information regarding CH operation
CH temperature control set to MAX
Release the securing clip and remove the diverter motor
Note.
The diverter motor can be removed without the need for draining
CH temperature control set to MAX
Release the securing clip and remove the diverter motor
Note.
The diverter motor can be removed without the need for draining
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the 4 minute pump purge to complete.
Observe the position of the diverter motor spindle.
Is it in the fully retracted position ?
Observe the position of the diverter motor spindle.
Is it in the fully retracted position ?
Isolate as per TOPs P4
and refit as necessary