Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the air intake
Remove the connector from the DHW flow sensor

Measurement:

Measure the resistance between pins 3, 4 and 6 on
connector X5 on the PCB to the disconnected DHW flow sensor connector, as per the table below;
Pin on connector X5DHW flow sensor connector
31
4 3
62

Expect continuity / zero resistance on each of the wires.
Also visually inspect the harness for good general condition.
Note.
Place the probe in the small holes on the PCB.