Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove spark electrode assembly from the appliance
Measurement:
Thoroughly inspect the electrode for;
Cracks and damage to the electrode ceramic
Distortion
Good general condition
Gap between spark electrodes approximately 4.0 mm
Resistance / continuity of electrode and lead,
expected resistance continuity / zero resistance
Also visually inspect the condition of the lead.
Note:
It may be necessary to clean the electrode first for continuity test.
expected resistance continuity / zero resistance
Also visually inspect the condition of the lead.
Note:
It may be necessary to clean the electrode first for continuity test.

Isolate as per TOPs P4
and refit as necessary