Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC voltage between pin 2 (black)
and pin 3 (black) on connector X2 during the pump purge.
Expect mains voltage to come and go
during the pump purge.
Note.
Place the probes in the small holes on the PCB.
and pin 3 (black) on connector X2 during the pump purge.
Expect mains voltage to come and go
during the pump purge.
Note.
Place the probes in the small holes on the PCB.

Isolate as per TOPs P4
and refit as necessary