Set Appliance State:
Ensure NO demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance, press and hold the reset button until the chimney
sweep button led flashes rapidly, then release the reset button.
The appliance will carry out a self-check, during this time the pump
will purge (PULSE) for approximately 4 minutes.
If the self-check has completed successfully, the reset button will be
the only LED illuminated (green) after the pump purge has completed.
sweep button led flashes rapidly, then release the reset button.
The appliance will carry out a self-check, during this time the pump
will purge (PULSE) for approximately 4 minutes.
If the self-check has completed successfully, the reset button will be
the only LED illuminated (green) after the pump purge has completed.