Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure the voltage between the blue wire and the
mains neutral at the incoming terminal block.
Test 2:
Measure the voltage between the black wire and the
mains neutral at the incoming terminal block.
Mains voltage should be present on both tests.
Note:
Wire colours refer to the PCB side (left hand side) of the terminal block.
Measure the voltage between the blue wire and the
mains neutral at the incoming terminal block.
Test 2:
Measure the voltage between the black wire and the
mains neutral at the incoming terminal block.
Mains voltage should be present on both tests.
Note: