Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Use Insulation Mat as required
Remove PCB cover
Remove PCB cover
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset appliance if it is in lockout.
Test 1:
Measure the voltage at the black wire (pin 5)
at connector X11 to a suitable earth point.
Mains voltage should be present.
Test 2:
Measure the voltage at the brown wire (pin 5)
at connector X13 to a suitable earth point.
Mains voltage should be present.
Test 1:
Measure the voltage at the black wire (pin 5)
at connector X11 to a suitable earth point.
Mains voltage should be present.
Test 2:
Measure the voltage at the brown wire (pin 5)
at connector X13 to a suitable earth point.
Mains voltage should be present.

Isolate as per TOPs P4
and refit as necessary