Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector from diverter valve
(Motor can also be unclipped and removed from boiler to improve access)
(Motor can also be unclipped and removed from boiler to improve access)
Measurement:
Test 1:
Measure the resistance between pin 1 and pin 2.
Test 2:
Measure the resistance between pin 3 and pin 2.
Resistances should be either approx. 8.5 kOhms or
greater than 1M Ohm depending on the motor position.
Measure the resistance between pin 1 and pin 2.
Test 2:
Measure the resistance between pin 3 and pin 2.
Resistances should be either approx. 8.5 kOhms or
greater than 1M Ohm depending on the motor position.

Isolate as per TOPs P4
and refit as necessary