Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X1 from the PCB
Measurement:
Test 1:
Measure the resistance between the Brown and Black wires.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between the Grey and Black wires.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between each of the three wires to a suitable earth point.
Resistance should be greater than 1M Ohm on each wire.
Measure the resistance between the Brown and Black wires.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between the Grey and Black wires.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between each of the three wires to a suitable earth point.
Resistance should be greater than 1M Ohm on each wire.

Isolate as per TOPs P4
and refit as necessary