Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove flow switch from appliance but leave connected electrically
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage from pin 5 at connector
X13 to a suitable earth point.
Is the voltage now approximately 4.8V DC?
Note:
This test can be carried out while appliance is doing self check.
X13 to a suitable earth point.
Is the voltage now approximately 4.8V DC?
Note:
This test can be carried out while appliance is doing self check.

Isolate as per TOPs P4
and refit as necessary