Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use Insulation Mat as required)
Disconnect plug from flow thermistor
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With the flow sensor disconnected the
appliance will immediately enter lockout.
This should make the appliance
run the pump constantly.
Measure the voltage between the brown
and blue wires at connector X4 on the PCB.
Mains voltage should be present.