Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect X4 from the PCB
Disconnect X4 from the PCB
Measurement:
Test 1:
Measure the resistance between the white and brown wires at the disconnected plug.
Resistance should be approximately 45 Ohms.
Test 2:
Measure the resistance between the black and blue wires at the disconnected plug.
Resistance should be approximately 125 Ohms.
Test 3:
Measure the resistance from each of the 4 wires to a suitable earth point.
Resistance should be greater than 1M Ohm on all 4 wires.
Measure the resistance between the white and brown wires at the disconnected plug.
Resistance should be approximately 45 Ohms.
Test 2:
Measure the resistance between the black and blue wires at the disconnected plug.
Resistance should be approximately 125 Ohms.
Test 3:
Measure the resistance from each of the 4 wires to a suitable earth point.
Resistance should be greater than 1M Ohm on all 4 wires.

Isolate as per TOPs P4
and refit as necessary