Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Attach U-gauge to gas inlet test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow 3 minute self check to complete.
As boiler attempts ignition monitor the inlet pressure.
At the sparking stage of the ignition sequence there should be a noticeable dip in the pressure, indicating the gas valve has opened however the pressure should remain above 18mbar (NG) or 37mbar (LPG) throughout.