Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Attach U-gauge to gas inlet test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow 3 minute self check to complete.
As boiler reaches the end of the self check monitor the inlet pressure.
Does the inlet pressure remain above
18mbar (NG) or 37mbar (LPG) throughout?
As boiler reaches the end of the self check monitor the inlet pressure.
Does the inlet pressure remain above
18mbar (NG) or 37mbar (LPG) throughout?