Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Gain access to PCB (use Insulation Mat as required)
Disconnect connector X1 from the PCB

Measurement:

Test 1:
Measure the resistance between the blue and white wires at the disconnected plug.
Resistance should be approximately 3.8kOhms.
Test 2:
Measure the resistance between the white wire at the disconnected plug to a suitable earth point.
Resistance should be greater than 1M Ohm.