Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X13 from the PCB
Measurement:
Test 1:
Measure the resistance between the Blue and Brown wires at the disconnected connector.
Expect approximately 11.4 kOhms.
Test 2:
Measure the resistance between the Brown wire at the disconnected connector and Earth.
Expect Resistance Open circuit
Test 3:
Measure the resistance between the Blue wire at the disconnected connector and Earth
Expected Resistance Open Circuit
Measure the resistance between the Blue and Brown wires at the disconnected connector.
Expect approximately 11.4 kOhms.
Test 2:
Measure the resistance between the Brown wire at the disconnected connector and Earth.
Expect Resistance Open circuit
Test 3:
Measure the resistance between the Blue wire at the disconnected connector and Earth
Expected Resistance Open Circuit

Isolate as per TOPs P4
and refit as necessary