Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Remove diverter valve motor from diverter body
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Is the diverter valve motor spindle in the CH position i.e. fully extended?
Note:
It is recommended to ensure the boiler has definitely fired for CH demand before checking the position of the spindle as the boiler incorporates a built in delay.
Note:
It is recommended to ensure the boiler has definitely fired for CH demand before checking the position of the spindle as the boiler incorporates a built in delay.
Isolate as per TOPs P4
and refit as necessary