Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Remove and thoroughly inspect the spark electrode assembly, check the ceramic for cracks and inspect the general condition.
Ensure the spark gap is 4mm +/- 0.5mm
Note:
Any gaskets or seals disturbed during this test should be checked for integrity and replaced if necessary.
Ensure the spark gap is 4mm +/- 0.5mm
Note:
Any gaskets or seals disturbed during this test should be checked for integrity and replaced if necessary.
Isolate as per TOPs P4
and refit as necessary