Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
DHW Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
With the connector attached to the pcb, measure the DC volts at the PCB connector X23 on the harness from each wire listed in the table to the neutral at incoming mains terminal strip.
Voltages should be approximately as follows;
Note: Ensure a good connection is made.
Voltages should be approximately as follows;
Note: Ensure a good connection is made.

Isolate as per TOPs P4
and refit as necessary