Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the i-controller (display pcb) from the front of the boiler
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pins 1-3 on the right hand connector to the display pcb and the neutral at the incoming mains terminal strip.
The Voltages should conform approximately to the table below:
The Voltages should conform approximately to the table below:
| Test | DC Volts | 1 | 11.7 |
| 2 | 0 |
| 3 | 15.3 |

Isolate as per TOPs P4
and refit as necessary