Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the mains cable to the pump
Measurement:
Test 1:
Measure the resistance between the Bottom and Middle pins.
Expect approximately 11.4kOhms.
Test 2:
Measure the Resistance between the Bottom pin and Earth
Expect Open Circuit.
Test 3:
Measure the resistance between the Middle pin and Earth
Expect Open Circuit.
Measure the resistance between the Bottom and Middle pins.
Expect approximately 11.4kOhms.
Test 2:
Measure the Resistance between the Bottom pin and Earth
Expect Open Circuit.
Test 3:
Measure the resistance between the Middle pin and Earth
Expect Open Circuit.

Isolate as per TOPs P4
and refit as necessary