Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
DHW Demand
Remove control box cover if necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure voltage between the green at connector X22 with the connector attached to the pcb and the neutral at the incoming mains terminal strip.
Expect approximately 5vdc.