Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect plug (red leads) from flow sensor.

Measurement:

Measure the Resistance across the two sensor terminals, also measure the approximate temperature at the sensors location.
Note:
Ensure the sensor is correctly attached to the pipe.
The resistance will vary according the boiler temperature but should conform approximately to the table below at the appropriate temperature to ensure it is within range and in calibration.
Temperature °CResistance in kOhms
2010
30 6.6
405.8
503.1
602
701.5
801.1