Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove control box cover if necessary
Run hot water tap at flow rate of 3 l/min
Run hot water tap at flow rate of 3 l/min
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between the Red wire on connector X22 (4th down from the top) and the neutral at the incoming mains terminal strip, with the connector attached to the PCB.
Expect a steady voltage of approximately 2.5vdc.
Is the voltage measured as expected?
Expect a steady voltage of approximately 2.5vdc.
Is the voltage measured as expected?

Isolate as per TOPs P4
and refit as necessary