Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Remove control box cover if necessary
Run hot water tap at flow rate of 3 l/min
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between the Red wire on connector X22 (4th connection up from the bottom) and a suitable earth, with the connector X22 attached to the PCB.
Expect a steady voltage of approximately 2.4 vdc.
Is the voltage measured as expected?