Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
CH Demand
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow appliance to fire and system to heat until boiler shuts down.
Isolate Mains Power to appliance as per TOP's P4

Check temperature of flow pipe close to the overheat stat
Disconnect the leads from the overheat stat
Measure resistance across the exposed terminals of the overheat stat. Expect resistance close circuit zero resistance
OPEN CIRCUIT MEASURED TEMP ABOVE 105°C FURTHER INVESTIGATION REQUIRED

OPEN CIRCUIT MEASURED TEMPERATURE BELOW 105°C

CLOSED CIRCUIT MEASURED