Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Remove and thoroughly inspect the spark electrode assembly and its ceramic for damage and good general condition
Ensure the spark gap is 4mm +/- 0.5mm
Note:
Check the condition of any seals and gaskets disturbed during this test and replace if necessary.
Ensure the spark gap is 4mm +/- 0.5mm
Note:
Check the condition of any seals and gaskets disturbed during this test and replace if necessary.
Isolate as per TOPs P4
and refit as necessary