Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between the PCB connector X23 blue wire and a suitable earth connection.
Expected voltage approximately ≤ 1.0 Vdc.
Note.
≤ is equal to or less than.
Expected voltage approximately ≤ 1.0 Vdc.
Note.
≤ is equal to or less than.

Isolate as per TOPs P4
and refit as necessary