Set Appliance State:
Mains Power Off
CH Demand
DHW Demand
DHW Temperature set to Max
CH Temperature set to Max
CH Temperature set to Max
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Run DHW tap and allow boiler to reach a reasonable working temperature.
Then run the CH and allow the appliance to fire and heat to a reasonable working temperature.
Note:
Some radiators can be turned off to reduce the time it takes for the central heating to reach a reasonable operating temperature.
Monitor the operation of the appliance.
Does the boiler shut down and show error code E110?
Then run the CH and allow the appliance to fire and heat to a reasonable working temperature.
Note:
Some radiators can be turned off to reduce the time it takes for the central heating to reach a reasonable operating temperature.
Monitor the operation of the appliance.
Does the boiler shut down and show error code E110?