Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove electrical connector to diverter valve
Remove diverter valve head from body (if required)
Remove diverter valve head from body (if required)
Measurement:
Test 1:
Measure the resistance between pin 1 and pin 2.
Test 2:
Measure the resistance between pin 3 and pin 2.
Resistances should be either approx. 6.0 kOhms or
greater than 1M Ohm depending on the motor position.
Measure the resistance between pin 1 and pin 2.
Test 2:
Measure the resistance between pin 3 and pin 2.
Resistances should be either approx. 6.0 kOhms or
greater than 1M Ohm depending on the motor position.

Isolate as per TOPs P4
and refit as necessary