Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Measure temp across cold mains inlet and DHW outlet using Performance Tester temp probes, as close to the secondary heat exchanger as possible
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow boiler to ignite and run on DHW.
Is the temperature rise approximately per the table?
Note: Flow rates lower than specified will result in a higher temperature rise and this must be taken into account when selecting the outcome of the test. To investigate a poor water flow rate from the tap CLICK HERE.
Is the temperature rise approximately per the table?
Note: Flow rates lower than specified will result in a higher temperature rise and this must be taken into account when selecting the outcome of the test. To investigate a poor water flow rate from the tap CLICK HERE.