Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
CASE OFF
OUTER CASE REMOVA
DOES FAN RUN ON DHW DEMAND
SELECTOR SWITCH ON HOT WATER
BURNER IGNITES AND ESTABLISHES
{SELHWCHON}
OPERATION DHW
MEASURE TEMP ACROSS
OPERATION CH
{SELHWCHON}
FLOW AND RETURN VALVES FULLY OPEN
CH THERMOSTAT SET TO MAX
OVERHEAT INVESTIGATION
OUT OF MODEL
E20 FAULT CODE
OUT OF MODEL
E50 FAULT CODE
OUT OF MODEL
E119 FAULT CODE
OUT OF MODEL
E125 FAULT CODE
OUT OF MODEL
E130 FAULT CODE
OUT OF MODEL
E160 FAULT CODE
OUT OF MODEL
FUSE FURTHER INVESTIGATION
OUT OF MODEL
E168 FAULT CODE
E168 FAULT CODE
T
POWER UP
{SELHWCHON}
ENSURE THERE ARE NO DEMANDS
BOILER ENTERS STANDBY MODE
{SELHWCHON}
ENSURE THERE ARE NO DEMANDS
E164 FAULT CODE
OUT OF MODEL
E28 FAULT CODE
HEADER FOR E28 FAULT CODE
SF OR P CALIBRATION FUNCTION
INTENTIONALLY BLANK - HEADER FOR FAULT CODE
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
HEADER FOR QADAI FLOW THERMISTOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI SPARK GENERATOR RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DHW SENSOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR DIVERTER VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
TEMP LOW
SENSOR - NTC (PRIMARY)
E156
MAINS VOLTAGE LESS THAN 180VAC
NO MOVEMENT
FLOW REGULATOR
NO AC VOLTAGESTANDY BY MODE
WIRING - FAN/IGNITER
FAN SUPPLY DC
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
NO FAN DC
PCB
FAN DOES NOT RUN
PCB
NO PRESSURE E119E164
SYSTEM PRESSURE
BLOCKED E119E164
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
E164
PUMP
NO SIGNAL
WIRING - DHW PRIORITY / SENSOR
STANDBY
FAN ASSEMBLY
POOR FLOW RATE
FLOW REGULATOR
FROST PROTECTION
SENSOR - NTC (DHW)
MAKING FLOW SWITCH
HOT WATER TAP OR PIPEWORK
STUCK MADE
FLOW REGULATOR
STUCK MADE
SENSOR - HALL EFFECT
SHORTED GIVING DEMAND
WIRING - DHW PRIORITY / SENSOR
FROST PROTECTION
SENSOR - NTC (PRIMARY)
CH NO DEMAND
PCB
BLOWN STAND BY MODE AT POWER UPB4 OP SEQ
FUSE 3AMP
BLOWN STANDBY MODE AT POWER UPFAN DOESNT RUNB4 OP SEQ
FUSE 2 AMP (LIVE)
BLOWNB4 OP SEQ
FUSE 2 AMP (NEUTRAL)
BLANK DISPLAYB4 OP SEQ
SENSOR - HALL EFFECT
BLANK DISPLAYB4 OP SEQ
WIRING - DHW PRIORITY / SENSOR
BLACK DISPLAYB4 OP SEQ
FAN ASSEMBLY
ERRATIC TEMPERATURE DISPLAY
SENSOR - NTC (PRIMARY)
FAN NOT RUNNING
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FAN NOT RUNNING E160
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
NO AC VOLTAGESTANDY BY MODE BLANK DISPLAY
WIRING - FAN/IGNITER
FAN NOT RUNNING BLANK DISPLAY
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FAN SUPPLY DC BLANK DISPLAY
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
STANDBY BLANK DISPLAY
FAN ASSEMBLY
E168
PUMP
E168
GAS VALVE
E168
MOTOR - 3 WAY VALVE
E168
SPARK GENERATOR
E168 AC
FAN ASSEMBLY
E168 DC
FAN ASSEMBLY
FAN RUNS DHWNO SUPPLY VOLTAGEFANE168
SENSOR - NTC (PRIMARY)
FAN RUNSNO SUPPLY VOLTAGEFANE168
DEVICE - SAFETY - FLUE
FAN RUNS DHWNO SUPPLY VOLTAGEFANE168
THERMOSTAT - LIMIT
NO FANNO SUPPLY VOLTAGEFANE168
SENSOR - NTC (DHW)
NO PRESSUREE168
SYSTEM PRESSURE
BLOCKEDE168
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
E168
ELECTRODE - IGNITION
E168
ELECTRODE - IONISATION
INSUFFICIENT
WATER SUPPLY
OPERATION CH - NOISY
TAP - ISOLATION - RETURN (FILTER)
E125 FAULT CODE
TAP - ISOLATION - RETURN (FILTER)
COOL HW
SENSOR - NTC (DHW)
DHW COOL RADS COOL
SENSOR - NTC (PRIMARY)
BLOCKAGE
3 WAY VALVE ASSEMBLY
BLOCKED
PIPE - PRESSURE SWITCH
EXPLOSIVE IGNITIOJN
GAS INLET PRESSURE
EXPLOSIVE IGNITION
LEAD - IGNITION ELECTRODE
EXPLOSIVE IGNITION
CONDENSER AND DRAIN
EXPLOSIVE IGNITION
FLUE
EXPLOSIVE IGNITION
ELECTRODE - IGNITION
EXPLOSIVE IGNITION
BURNER
EXPLOSIVE IGNITION
HEAT EXCHANGER - BASIC
EXPLOSIVE IGNITION
FAN - PRESSURE SENSING VENTURI
EXPLOSIVE IGNITION
PIPE - PRESSURE SWITCH
GAS VALVE DAMAGED PCB
PCB AND GAS VALVE
BURNER DOES NOT ESTABLISH
GAS INLET PRESSURE
FAULTY SOLENOIDS
GAS VALVE
BLOCKEDBLOCKED
CONDENSER AND DRAIN
SPARKING WRONG POSITION
ELECTRODE - IGNITION
CHOKEDBLOCKED
BURNER
BURNER DOES NOT IGNITEBLOCKED
HEAT EXCHANGER - BASIC
BLOCKED OR RESTRICTED
FAN - PRESSURE SENSING VENTURI
NO DROP
FAN - PRESSURE SENSING VENTURI
NO SPARK
WIRING - FAN/IGNITER
NO SPARKING
LEAD - IGNITION ELECTRODE AND EARTH
CASE REMOVAL
DIRECTION CHOICE OR CONTINUE
NOT ESTABLISHING
CONDENSER AND DRAIN
E125
DEVICE - SAFETY - FLUE
BURNER BAFFLES OUT
GAS INLET PRESSURE
NO CH VOLTAGE
PCB
BLOCKED 2
CONDENSER AND DRAIN
DIVERTER CH
WIRING - V3V / PLUG / GAS VALVE
OVERHEAT
TAP - ISOLATION - RETURN (FILTER)
DIVERTER CH DHW DIFF OK
WIRING - V3V / PLUG / GAS VALVE
OVERHEAT DHW DIFF OK
TAP - ISOLATION - RETURN (FILTER)
BURNER BAFFLES OUT
BURNER
DHW COOL
3 WAY VALVE ASSEMBLY
POOR DHW
BURNER
OPERATION DHW - DHW COOL RADS COOL - FLUEWAYS
HEAT EXCHANGER - BASIC
NO DISPLAY
WIRING - CONNECTOR
BURNER BAFFLES OUT
FLUE
FAN RUNS DHWNO SUPPLY VOLTAGEFANOH
THERMOSTAT - LIMIT
NO RESET OVERHEAT
SWITCH - SELECTOR - 4 POSITION
FAN RUNSNO SUPPLY VOLTAGEFANE130
DEVICE - SAFETY - FLUE
NO RESET E130
SWITCH - SELECTOR - 4 POSITION
BURNER DOES NOT IGNITEBLOCKEDE130
HEAT EXCHANGER - BASIC
E28
DEVICE - SAFETY - FLUE
E130
FLUE
NO CH SWITCH
SWITCH - SELECTOR - 4 POSITION
MISSING
CABLE - INTEGRAL TIMER
NO CH 2
PCB
NO CH SWITCH DHW NOISY
SWITCH - SELECTOR - 4 POSITION
MISSING DHW NOISY
CABLE - INTEGRAL TIMER
STUCK AFTER DEMAND
FLOW REGULATOR
BLANK FOR LITE DIAGNOSTIC
Z DIRECTION CHOICE OR CONTINUE
BLANK FOR QADAI
Z DIRECTION CHOICE OR CONTINUE
QADAI
SENSOR - NTC (PRIMARY)
QADAI
GAS VALVE
QADAI
SPARK GENERATOR
QADAI
PUMP
QADAI AC
FAN ASSEMBLY
QADAI
DEVICE - SAFETY - FLUE
QADAI
SENSOR - NTC (DHW)
QADAI
MOTOR - 3 WAY VALVE
BURNER IGNITES BUT BAFFLES OUT
FAN - PRESSURE SENSING VENTURI
OPEN CIRCUIT
CABLE - ELECTRODE - FLAME SENSING
FAULTY
ELECTRODE - IONISATION
BURNER IGNITES BUT DOES NOT ESTABLISH
FAN - PRESSURE SENSING VENTURI
OPERATION DHW DHW RUNS HOT THEN COLD
SENSOR - NTC (DHW)
OPERATION DHW DHW RUNS HOT THEN COLD
SENSOR - NTC (PRIMARY)
PREHEAT SATISFACTORY3
3 WAY VALVE ASSEMBLY
BLOCKED PREHEAT SAT3
HEAT EXCHANGER - DHW
FAN RUNSDHW OPERATION DHW TOO HOT
SENSOR - NTC (DHW)
FLAME BAFFLES
HEAT EXCHANGER - BASIC
DHW HOT THEN COLD
PUMP
BOILER NOISY
PUMP
NO PUMP VOLTAGE
PCB
UNDER PRESSURE
EXPANSION VESSEL
CLOSED
FLOW AND RETURN VALVES
RADS COOL
PUMP
FOR TYPE DIAG PROCEDURE
DIRECTION CHOICE OR CONTINUE
BYPASS
3 WAY VALVE ASSEMBLY
BLOCKED
TAP - ISOLATION - RETURN (FILTER)
NOISY BOILER
3 WAY VALVE ASSEMBLY
BOILER NOISY
SENSOR - NTC (PRIMARY)
F5 FAULT CODE
PUMP
OVERHEAT
SENSOR - NTC (DHW)
OVERHEAT
SENSOR - NTC (PRIMARY)
LOW TEMP
GAS INLET PRESSURE
UNABLE TO SET
GAS VALVE
DIVERTER CHTEST
WIRING - V3V / PLUG / GAS VALVE
DIVERTOR
WIRING - V3V / PLUG / GAS VALVE
VOLTAGE DIVERTER
PCB
NO PUMP VOLTAGE2
PCB
FAN RUNS DHWNO SUPPLY VOLTAGEFANE20
SENSOR - NTC (PRIMARY)
NO FANNO SUPPLY VOLTAGEFANE50
SENSOR - NTC (DHW)
NO PRESSURE E119
SYSTEM PRESSURE
BLOCKED E119
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
E125
PUMP
E125
SENSOR - NTC (PRIMARY)
E125
SENSOR - NTC (DHW)
NO RESET
SWITCH - SELECTOR - 4 POSITION
RESRICTIONE125
HEAT EXCHANGER - DHW
E130
CONDENSER AND DRAIN
NOISY
CONDENSER AND DRAIN
CHOKEDBLOCKEDE130
BURNER
FAN RUNS DHWNO SUPPLY VOLTAGEFAN
SENSOR - NTC (PRIMARY)
NO FANNO SUPPLY VOLTAGEFAN
SENSOR - NTC (DHW)
NO PRESSURE
SYSTEM PRESSURE
BLOCKED
SWITCH - PRESSURE - HEATING (WATER PRESSURE)
FAN RUNSNO SUPPLY VOLTAGEFAN
DEVICE - SAFETY - FLUE
FAN RUNS DHWNO SUPPLY VOLTAGEFAN
THERMOSTAT - LIMIT
E160
WIRING - FAN/IGNITER
E160
PCB
E160
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FAULT CODES
Z DIRECTION CHOICE OR CONTINUE
FAN SIGNAL E160
FAN ASSEMBLY
FUSE FURTHER INVESTIGATION
GAS VALVE
DC HARNESS
FAN ASSEMBLY
FUSE BLOWING
MOTOR - 3 WAY VALVE
FUSE BLOWING
FAN ASSEMBLY
POOR FLOW RATE
TAP - ISOLATION - DHW INLET
WATER PRESSURE E119
WIRING - DHW PRIORITY / SENSOR
NO MOVEMENT
SENSOR - HALL EFFECT
VOLTS TO TURBINE
PCB
E119 FAULTE164
PCB
WATER PRESSURE E119E164
WIRING - DHW PRIORITY / SENSOR
F5 FAULTE125E164
PUMP
PUMP2E125E164
WIRING - V3V / PLUG / GAS VALVE
DHW
FROST PROTECTION
NO DEMAND
KIT - ELECTRO/MECHANICAL
FURTHER INVESTIGATION F1B4 OP SEQ
Z DIRECTION CHOICE OR CONTINUE
FURTHER IN VESTIGATION F2FAN DOESNT RUNB4 OP SEQ
Z DIRECTION CHOICE OR CONTINUE
FURTHER INVESTIGATION F3B4 OP SEQ
Z DIRECTION CHOICE OR CONTINUE
BLANK DISPLAYB4 OP SEQ
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FURTHER INVESTIGATION LED PCB FAULT TO FAN RUNS BURNER IGNITES AND ESTABLISHESB4 OP SEQ
Z REDIRECTS BY HTML LINK
ERRATIC TEMPERATURE DISPLAY
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
RUNNING SLOW
FAN ASSEMBLY
VOLTAGE NO MOVEMENTSTANDY BY MODE
FAN ASSEMBLY
VOLTAGE NO MOVEMENTSTANDY BY MODE E160
FAN ASSEMBLY
VOLTAGE NO MOVEMENTSTANDY BY MODE BLANK DISPLAY
FAN ASSEMBLY
E168
WIRING - V3V / PLUG / GAS VALVE
E168 GAS VALVE
WIRING - V3V / PLUG / GAS VALVE
DIVERTOR E168
WIRING - V3V / PLUG / GAS VALVE
E168 IGNITER
WIRING - FAN/IGNITER
E168 AC
WIRING - FAN/IGNITER
E168 FAN DC
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
PRIMARYNO SUPPLY VOLTAGEFANE168
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FLUE STATE168
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
OH STATE168
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
DHW SENSORNO SUPPLY VOLTAGEFANE168
WIRING - DHW PRIORITY / SENSOR
WATER PRESSURE SWITCHE168
WIRING - DHW PRIORITY / SENSOR
RESTRICTEDE125
HEAT EXCHANGER - BASIC
BLOCKED
HEAT EXCHANGER - DHW
OPERATION DHW - HOT COLD
HEAT EXCHANGER - BASIC
EXPLOSIVE IGNITION
GAS VALVE
SPARKING NO IGNITION
GAS INLET PRESSURE
NO GV VOLTAGE
PCB
GAS VALVE HARNESS DAMAGED PCB
PCB AND GAS VALVE HARNESS
GV VOLTAGEPASS
WIRING - V3V / PLUG / GAS VALVE
MECHANICALPASS
GAS VALVE
NOT OPENING RESISTANCE OK
GAS VALVE
EXPLOSIVE IGNITION
SPARK GENERATOR
SPARKING OCCURS
ELECTRODE - IGNITION
NO SPARK - RESISTANCE
SPARK GENERATOR
NO SPARK
SPARK GENERATOR
E125 FLUE STAT
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
NOT MOVING TO CH
MOTOR - 3 WAY VALVE
RESRICTION
HEAT EXCHANGER - DHW
NOT MOVING TO CH DHW DIFF OK
MOTOR - 3 WAY VALVE
DHW TEMP LOW
HEAT EXCHANGER - DHW
OPERATION DHW - DHW COOL RADS COOL - WATERWAYS
HEAT EXCHANGER - BASIC
NO DISPLAY
WIRING - CONNECTOR / SELECTOR SWITCH
NO FANB4 OP SEQ
SWITCH - SELECTOR - 4 POSITION
FLAME BAFFLING
GAS VALVE
OH STATOH
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FLUE STATE130
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
NO RESETE130
PCB
E130
NO FAULT FOUND FLUE OVERHEAT
E28
PCB
E28
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
NO CH
PCB
NO CH3
PCB
NO SWITCH BACK
KIT - ELECTRO/MECHANICAL
NO CH DHW NOISY
PCB
NO CH3 DHW NOISY
PCB
NO SWITCH BACK DHW NOISY
KIT - ELECTRO/MECHANICAL
STUCK AFTER DEMAND
SENSOR - HALL EFFECT
NORMAL OPERATION
CALIBRATION FUNCTION
SENSOR TEMP FLOW
RESULT AS EXPECTED
GAS VALVE
RESULT AS EXPECTED
PCB POWER TO GAS VALVE
RESULT AS EXPECTED
SPARK GENERATOR
RESULT AS EXPECTED
PUMP
RESULT AS EXPECTED
PCB POWER TO PUMP
RESULT AS EXPECTED
FAN AC
RESULT AS EXPECTED
PCB POWER TO FAN AC
RESULT AS EXPECTED
SENSOR FLUE
RESULT AS EXPECTED
DHW SENSOR
RESULT AS EXPECTED
DIVERTER VALVE HEAD
RESULT AS EXPECTED
NO RETIFICATION
PCB
DHW NOISY KETTLING
HEAT EXCHANGER - DHW
LETBY PREHEAT3
3 WAY VALVE ASSEMBLY
VOLTAGE NOT RUNNING
PUMP
PUMP
WIRING - V3V / PLUG / GAS VALVE
EXPANSION CONNECTION
BLOCKAGE
F5 FAULT
PUMP
OVERHEAT
TEMPERATURE OVERHEAT
EXCESSIVE TEMP
PCB
CUTTING OFF
THERMOSTAT - LIMIT
DHW NOISY KETTLING
HEAT EXCHANGER - BASIC
NOT MOVING TO CHTEST
MOTOR - 3 WAY VALVE
PREHEAT SATISFACTORY3
MOTOR - 3 WAY VALVE
CH OPERATION NOISY
HEAT EXCHANGER - BASIC
PUMP2
WIRING - V3V / PLUG / GAS VALVE
PRIMARYNO SUPPLY VOLTAGEFANE20
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
E20
PCB
DHW SENSORNO SUPPLY VOLTAGEFANE50
WIRING - DHW PRIORITY / SENSOR
E50
PCB
E119 FAULT
PCB
F5 FAULTE125
PUMP
PUMP2E125
WIRING - V3V / PLUG / GAS VALVE
NO RESET
PCB
ALL OKAY
BOILER LOCKOUT
PRIMARYNO SUPPLY VOLTAGEFAN
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
DHW SENSORNO SUPPLY VOLTAGEFAN
WIRING - DHW PRIORITY / SENSOR
WATER PRESSURE SWITCH
WIRING - DHW PRIORITY / SENSOR
FLUE STAT
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
OH STAT
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
PCB FUSE BLOWING
FUSE GONE PCB
FUSE
WIRING - V3V / PLUG / GAS VALVE
FUSE2
WIRING - V3V / PLUG / GAS VALVE
FUSE
WIRING - OVERHEAT SENSOR/FLUE THERMOSTAT/FAN
FUSE GAS VALVE
WIRING - V3V / PLUG / GAS VALVE
FUSE
WIRING - FAN/IGNITER
POOR FLOW RATE
HEAT EXCHANGER - DHW
PUMP2E125DHW NOISY
WIRING - V3V / PLUG / GAS VALVE
NO VOLTAGE PRESENT
CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION
FAN RUNS CONTINUALLY
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
FAN DOES NOT RUN ON SELF CHECK
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
VOLTAGE STAYS THE SAME
CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION
DHW OR CH DEMAND LED ILLUMINATED
CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE
DISPLAY DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM POWER UP
DISPLAY ILLUMINATES BUT TEMPERATURE DISPLAYED ERRATIC
CHARACTERISTIC TEST FROM POWER UP
FAN RUNS CONTINUOUSLY AT HIGH SPEED
CHARACTERISTIC TEST FROM FAN RUNS SELF CHECK
FAN DOESN'T RUN
CHARACTERISTIC TEST FROM FAN RUNS SELF CHECK
EXPLOSIVE OR DELAYED IGNITION
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
SPARKING OCCURS BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
FAN RUNS SPARKING DOES NOT OCCUR
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT BAFFLES OUT OR LIFTS OFF
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
GAS INLET PRESSURE LOW OR DROPS BELOW MINIMUM
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
GAS INLET PRESSURE OK BUT DOES NOT DROP
CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP
VOLTAGE MISSING
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER
NO INTEGRAL TIMER FITTED
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER
VOLTAGE MISSING
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER
NO INTEGRAL TIMER FITTED
CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL RADS COOL
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL RADS HOT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW NOISY KETTLING
CHARACTERISTIC TEST FROM OPERATION DHW
DHW RUNS HOT THEN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
BOILER DOES NOT REACT TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION (FOR HEAT EX DIAG)
BOILER KETTLES
CHARACTERISTIC TEST FROM CH OPERATION (FOR HEAT EX DIAG)
BOILER NOISY
CHARACTERISTIC TEST FROM OPERATION CH
BOILER UP TO TEMP RADS COLD
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMP LOW SYSTEM TEMP LOW
CHARACTERISTIC TEST FROM OPERATION CH
SYSTEM PRESSURE RISE EXCESSIVE
CHARACTERISTIC TEST FROM OPERATION CH
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMP GOES ABOVE 90 DEGREES AND DOESNT CUT OFF
CHARACTERISTIC TEST FROM CH TEST OVERHEAT
BOILER LOCKS OUT ON OVERHEAT BEFORE REACHING 85 DEGREES
CHARACTERISTIC TEST FROM CH TEST OVERHEAT
TEMP DIFFERENTIAL NOT OK LOCAL BOILING
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
DIFFERENTIAL OK SYSTEM NOISE
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
14/11/2022 14:30:58 2211_1_50_1 27/01/2023 11:18:48
20/01/2023 09:58:34
DHW FLOW SWITCH OPERATION
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE WATER PRESSURE SWITCH
DISCONNECT THE WIRES
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
VOLTAGE FROM SWITCH LIVE
{SELHWCHON}
NO DEMANDS FOR CH
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FUSE F2 ( APPLIANCE)
REMOVE CONTROL BOX COVER
REMOVE THE FUSE AND HOLDER FROM THE LIVE (BROWN)
RESISTANCE FAN (DC)_FUSE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE IGNITER
REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
RESISTANCE FAN DC
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
RESISTANCE SENSOR OVERHEAT STAT
UNPLUG THE LEAD FROM THE OVERHEAT STAT
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
TURN
DIVERTER VALVE BLOCKAGE
ISOLATE COLD MAINS I
RESISTANCE ELECTRODE LEAD
REMOVE SPARK AND EARTH LEADS FROM ELECTRODE AND SPARK GENERATOR
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE SPARK GENERATOR AND LEADS
REMOVE SPARK LEAD AND EARTH WIRE FROM ELECTRODE
RESISTANCE ELECTRODE LEAD
REMOVE SPARK AND EARTH LEADS FROM ELECTRODE AND SPARK GENERATOR
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
TURN
DIVERTER VALVE BLOCKAGE
ISOLATE COLD MAINS I
VOLTAGE SELECTOR SWITCH
SELECTOR SWITCH IN HOT WATER
VOLTAGE SELECTOR SWITCH INPUT
SELECTOR SWITCH IN HOT WATER
RESISTANCE SENSOR OVERHEAT STAT
UNPLUG THE LEAD FROM THE OVERHEAT STAT
RESISTANCE SELECTOR SWITCH (RESET)
{SELHWCHON}
REMOV
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
RESISTANCE SELECTOR SWITCH (RESET)
{SELHWCHON}
REMOV
RESISTANCE SENSOR FLUE OVERHEAT AND HARNESS
REMOVE THE CONNECTOR X401 FROM THE CONTROL BOX
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
INSPECTION FLOW SWITCH ASSEMBLY
ISOLATE MAINS WATER
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
GAS VALVE VOLTAGE (PCB)
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE IGNITER
REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
VOLTAGE DIVERTER VALVE PCB
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
TURN
VOLTAGE DIVERTER VALVE PCB CH
FUNCTION SELECTOR IN
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE WATER PRESSURE SWITCH
DISCONNECT THE WIRES
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SELECTOR SWITCH (RESET)
{SELHWCHON}
REMOV
RESISTANCE SENSOR FLUE OVERHEAT AND HARNESS
REMOVE THE CONNECTOR X401 FROM THE CONTROL BOX
IS FAN RUNNING
{SELHWCHON}
RESISTANCE FAN HARNESS AC
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE SENSOR FLUE OVERHEAT STAT
REMOVE THE FLUE SENSOR FROM THE TOP OF THE HEAT EXCHANGER
(TWIST BAYONET FITTING)
RESISTANCE SENSOR OVERHEAT STAT
UNPLUG THE LEAD FROM THE OVERHEAT STAT
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE GAS VALVE
DISCONNECT THE LEAD FROM THE GAS VALVE
RESISTANCE PUMP
DISCONNECT THE MAINS CABLE TO THE PUMP
RESISTANCE FAN DC
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
RESISTANCE AC FAN
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
RESISTANCE DIVERTER VALVE HEAD
REMOVE DIVERTER VALVE HEAD FROM BODY
VOLTAGE AT PUMP
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
VOLTAGE PUMP AT PCB
{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
INSPECTION FLOW SWITCH ASSEMBLY
ISOLATE MAINS WATER
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS AC
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE DHW FLOW SWITCH HARNESS
REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH
OBSERVATION ISOLATE DHW DOES DHW DEMAND STOP
ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE
OBSERVATION REMOVE HALL SENSOR DOES DHW DEMAND STOP
REMOVE DHW HALL SENSOR FROM FLOW VALVE
OBSERVATION DISCONNECT HALL SENSOR DOES DHW DEMAND STOP
REMOVE DHW HALL SENSOR FROM FLOW VALVE
REMOVE CONNECTOR FROM THE HALL SENSOR AND MAKE SAFE
RESISTANCE DHW FLOW SWITCH HARNESS
REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
IS VOLTAGE PRESENT FROM INTEGRAL TIMER
{SELHWCHON}
GAIN
VOLTAGE MAINS POWER INPUT TO APPLIANCE
REMOVE CONTROL BOX COVER
VOLTAGE AT PCB MAINS
REMOVE CONTROL BOX COVER
REMOVE DHW FLOW SWITCH DOES DISPLAY NOW WORK
REMOVE DHW HALL SENS
REMOVE CONNECTOR X400 DOES DISPLAY NOW WORK
REMOVE CONNECTOR X400 FROM PCB
FAN RUNS SELF CHECK
SELECTOR SWITCH TO HOT WATER
REMOVE FAN CONNECTOR DOES DISPLAY NOW WORK
REMOVE CONNECTOR X401 FROM PCB
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS AC
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
RESISTANCE DIVERTER VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY
RESISTANCE IGNITER AND HARNESS
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FAN AND HARNESS AC
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE FAN AND HARNESS DC
DISCONNECT CONNECTOR X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE SENSOR FLUE OVERHEAT AND HARNESS
REMOVE THE CONNECTOR X401 FROM THE CONTROL BOX
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH
DISCONNECT THE WIRES
INSPECTION ELECTRODE SPARK GAP
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
INSPECTION DETECTION ELECTRODE
DISCONNECT THE LEAD FROM THE DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE FROM BURNER
WATER SUPPLY TO PREMISES
TURN ON A COLD WATER TAP
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATURE CLAMPS
ON FLOW AND RETURN PIPES AS SHOWN
DHW THERMOSTAT ON MAX
GAS INLET PRESSURE
{SELHWCHON}
SET D
CAN SPARKING BE SEEN (EXPLOSIVE IGN)
{SELHWCHON}
REMOV
INSPECTION ELECTRODE SPARK GAP
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
GAS INLET PRESSURE
{SELHWCHON}
SET D
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
GAS INLET PRESSURE
{SELHWCHON}
SET D
PRESSURE GAS INLET AND DROP
{SELHWCHON}
SET D
GAS VALVE VOLTAGE (PCB)
SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS
DISCONNECT CONNECTOR MARKED X3 FROM PCB
INSPECTION ELECTRODE SPARK GAP
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
CAN SPARKING BE SEEN
{SELHWCHON}
REMOV
RESISTANCE SPARK GENERATOR HARNESS
REMOVE CONNECTOR FROM SPARK GENERATOR
REMOVE CONNECTOR X2 FROM THE PCB
VOLTAGE SPARK GENERATOR
{SELHWCHON}
GAIN
VOLTAGE SPARK GENERATOR WITH LEAD
{SELHWCHON}
GAIN
RESISTANCE SENSOR FLUE OVERHEAT AND HARNESS
REMOVE THE CONNECTOR X401 FROM THE CONTROL BOX
TEMPERATURE DIFFERENTIAL CH
{SELHWCHON}
TURN
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATURE CLAMPS
ON FLOW AND RETURN PIPES AS SHOWN
DHW THERMOSTAT ON MAX
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
VOLTAGE FROM SELECTOR SWITCH
{SELHWCHON}
CH THERMOSTAT TO MAX
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE FROM EXTERNAL CONTROLS
{SELHWCHON}
CH THERMOSTAT TO MAX
RESISTANCE HARNESS EXTERNAL CONTROLS TO PCB
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE FROM INTEGRAL TIMER
{SELHWCHON}
VOLTAGE TO INTEGRAL TIMER
{SELHWCHON}
VOLTAGE LINKED CONNECTOR
{SELHWCHON}
VOLTAGE FROM SELECTOR SWITCH
{SELHWCHON}
CH THERMOSTAT TO MAX
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE FROM EXTERNAL CONTROLS
{SELHWCHON}
CH THERMOSTAT TO MAX
RESISTANCE HARNESS EXTERNAL CONTROLS TO PCB
REMOVE CONNECTOR X3 FROM THE PCB
VOLTAGE FROM INTEGRAL TIMER
{SELHWCHON}
VOLTAGE TO INTEGRAL TIMER
{SELHWCHON}
VOLTAGE LINKED CONNECTOR
{SELHWCHON}
OBSERVATION DISCONNECT EXTERNAL CONTROLS
DISCONNECT EXTERNAL
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
INSPECTION PRESSURE SENSING VENTURI
REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY
RESISTANCE DETECTION LEAD
REMOVE BOTH ENDS OF THE FLAME SENSE HARNESS, FROM THE ELECTRODE AND FROM X501 ON THE PCB
INSPECTION DETECTION ELECTRODE
DISCONNECT THE LEAD FROM THE DETECTION ELECTRODE
REMOVE DETECTION ELECTRODE FROM BURNER
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
GAS INLET PRESSURE
{SELHWCHON}
SET D
INSPECTION DIVERTER VALVE DHW POSITION
SELECTOR SWITCH IN HOT WATER
REMOVE DIVERTER VALVE MOTOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
CH OPERATION (FOR HEAT EX DIAG)
{SELHWCHON}
FLOW AND RETURN VALVES FULLY OPEN
CH THERMOSTAT SET TO MAX
INSPECTION DIVERTER VALVE SPINDLE
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
INSPECTION HEAT EXCHANGER DHW
DRAIN PRIMARY CIRCUIT OF BOILER DOWN
TURN OFF HW ISOLATION VALVE
COMBUSTION READINGS
{SELHWCHON}
REMOVE COMBUSTION TESTING POINT CAP FROM BOILER
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
EXPANSION VESSEL PRESSURE
BOILER DISCHARGED
INSPECTION DIVERTER VALVE POSITION CH
{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR
BYPASS PIPE TEMPERATURE
{SELHWCHON}
USE T
INSPECTION RETURN FILTER
DRAIN BOILER HEATING CIRCUIT
DIVERTER BLOCKAGE CH
ISOLATE COLD MAINS I
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH FGA TEMPERATURE CLAMPS
ON FLOW AND RETURN PIPES AS SHOWN
DHW THERMOSTAT ON MAX
CH TEST OVERHEAT
{SELHWCHON}
TURN
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
RESISTANCE DIVERTER HARNESS
REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR
TEMPERATURE DIFFERENTIAL FLOW RETURN
{SELHWCHON}
CH TH
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY
REMOVE THE LEAD FROM THE FLOW SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE THE LEAD FROM THE DHW SENSOR
CH TEST LOCKOUT
{SELHWCHON}
TURN
HW TEST LOCKOUT
SELECTOR SWITCH TO H
INSPECTION BURNER
REMOVE THE FRONT OF THE COMBUSTION CHAMBER
RESISTANCE FAN HARNESS
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
REMOVE THE PLUG X401 FROM THE PCB
RESISTANCE SENSOR TEMP DHW AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE WATER PRESSURE SWITCH AND HARNESS
REMOVE THE PLUG X400 FROM THE PCB
RESISTANCE SENSOR FLUE OVERHEAT AND HARNESS
REMOVE THE CONNECTOR X401 FROM THE CONTROL BOX
RESISTANCE WATER PRESSURE SWITCH
DISCONNECT THE WIRES
RESISTANCE OVERHEAT STAT AND HARNESS
UNPLUG CONNECTOR X401 FROM THE PCB
VOLTAGE AC TO FAN
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE FAN SUPPLY
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
VOLTAGE DC FROM FAN
{SELHWCHON}
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE FAN AND HARNESS DC
DISCONNECT CONNECTOR X401 FROM THE PCB
RESISTANCE FAN AND HARNESS AC
REMOVE CONNECTOR X2 FROM THE PCB
RESISTANCE DIVERTER VALVE AND HARNESS
REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY
INSPECTION FLOW SWITCH ASSEMBLY
ISOLATE MAINS WATER
System Information
- Total Tests: 700
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control