Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector A8 from the PCB
Remove diverter valve head from body
Remove diverter valve head from body
Measurement:
Test 1:
If the spindle is extended test between pins 1 and 3.
Expect approximately 9 Kohms.
If the spindle is retracted test between pins 1 and 5.
Expect approximately 9 Kohms.
If the spindle is not fully in one position test between
pins 1 & 3 then 1 & 5.
Expect approximately 9 Kohms.
Test 2
Measure the resistance between pins 1, 3 and 5 to earth.
Expected resistance on each test 1 Mohm or greater.
If the spindle is extended test between pins 1 and 3.
Expect approximately 9 Kohms.
If the spindle is retracted test between pins 1 and 5.
Expect approximately 9 Kohms.
If the spindle is not fully in one position test between
pins 1 & 3 then 1 & 5.
Expect approximately 9 Kohms.
Test 2
Measure the resistance between pins 1, 3 and 5 to earth.
Expected resistance on each test 1 Mohm or greater.

Isolate as per TOPs P4
and refit as necessary