Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
At the start of the XSol model both jumpers had to be removed which means the ignition fan speed is set to "normal" which is 2800rpm.
If the appliance initially had only a red jumper fitted it may be that the blue one had been removed previously to lower the ignition fan speed due to poor ignition.
If this was the case refit the red jumper and then click here to carry out the observation burner ignites test again - this will have also reactivated the intelligent preheat.
If both/neither jumpers were fitted or you have tried replacing the red jumper and it has not improved the ignition (as advised above) then click continue below.
For further information regarding jumper settings and the operation of the intelligent preheat click here.