Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the leads from the electrodes and carefully remove them from the combustion box door.
Measurement:
Thoroughly inspect the electrodes as below:
Ceramics not cracked.
Electrodes not warped or distorted.
No build-up of contamination on electrodes.
Detection electrode approx. 18mm in length (not burnt down).
Spark gap is 3.5mm +/- 0.5mm.
Measure the resistance across each of the 3 electrodes.
Expect continuity / zero resistance.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary.
Measure the resistance across each of the 3 electrodes.
Expect continuity / zero resistance.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary.

Isolate as per TOPs P4
and refit as necessary