Set Appliance State:
Turn Hot Water Tap On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow boiler to ignite and run on DHW.
With a flow rate as listed in the table below a temperature rise of approximately 35°C is expected.
Does the hot water operate satisfactorily and is the temperature rise as expected?
Note:
A lower flow rate will produce a greater temperature rise.
If you wish to investigate a poor DHW flow rate click HERE
With a flow rate as listed in the table below a temperature rise of approximately 35°C is expected.
| Appliance | Flow Rate |
| 80 HE | 10 l/min | 100 HE | 12 l/min | 133 HE | 16 l/min |
Does the hot water operate satisfactorily and is the temperature rise as expected?
Note:
A lower flow rate will produce a greater temperature rise.
If you wish to investigate a poor DHW flow rate click HERE