Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove DHW microswitch
Remove CH pump proving microswitch and
fit to the DHW differential valve
Disconnect connector A5 from PCB

Measurement:

Test 1:
Measure for continuity across connection 3 (red wire) and
connection 4 (red wire) at connector A5 on the main PCB.
Expect open circuit.
Hot water tap ON
Test 2:
Repeat test measure for continuity across connection 3 (red wire) and connection 4 (red wire) at connector A5 on the main PCB.
Expect continuity (short circuit).
After test completed refit DHW microswitch.