Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Selector switch to Off position
CH temperature selector to Min
DHW temperature selector to Max
Attach crocodile clip to black/orange wire on the air pressure switch and a suitable neutral
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Selector switch to DHW position.
Allow fan to run.
Measure voltage.
Mains voltage should be present.