Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X14 from the PCB
Measurement:
Test 1:
Measure the resistance between the brown and blue wires on X14 connector.
Resistance should be approximately 160 Ohms.
Test 2:
Measure the resistance between the brown wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between the brown and blue wires on X14 connector.
Resistance should be approximately 160 Ohms.
Test 2:
Measure the resistance between the brown wire on X14 connector
to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary