Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
Disconnect plug from diverter motor and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1:
Press the reset button on the front of the appliance and while the boiler runs its start-up sequence measure the dc voltage between pin 7 and a suitable earth.
Expect voltage to fluctuate between 0V DC, 12V DC and 22V DC before settling on 0V DC after approximately 5 seconds.
Repeat test on pin 8.
Test 2:
Press the reset button on the front of the appliance and while the boiler runs its start up sequence measure the dc voltage between pin 15 and a suitable earth.
Expect voltage to fluctuate between 0V DC, 12V DC and 22V DC before settling on 22V DC after approximately 5 seconds.
Repeat test on pin 16.