Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the connector from the display PCB
Remove the display PCB from the facia
Remove the connector from the display PCB
Remove the display PCB from the facia
Measurement:
Measure the resistance between the two furthest right terminals on the display PCB.
Expect a resistance of approximately 200 - 300 ohms.
Is the resistance measured as expected?
Expect a resistance of approximately 200 - 300 ohms.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary