Set Appliance State:

Mains Reset Switch OFF
Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Ensure the boiler is cool so that there is demand for preheat
Set DHW temperature selector to ECO
Disconnect J4 connector at PCB and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Mains reset switch ON.
Measure voltage across the red and blue leads
(terminals 1 and 5).
Expected voltage approximately 37 volts DC.
Note:Test shall be carried out with connector in-situ, attached to the fan.