Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove rear control panel cover to expose main PCB.
Remove rear control panel cover to expose main PCB.
Measurement:
Remove pump connector marked H1 on the main PCB
Test 1:
Measure resistance across the live (brown lead) and neutral (blue lead) connection on the connector marked H1 on the main PCB.
Expected Resistance Approx 160 Ohms
Test 2:
Measure resistance across the live (brown lead) and
a suitable Earth
Expected resistance O.L or greater than 1MOhm
Test 1:
Measure resistance across the live (brown lead) and neutral (blue lead) connection on the connector marked H1 on the main PCB.
Expected Resistance Approx 160 Ohms
Test 2:
Measure resistance across the live (brown lead) and
a suitable Earth
Expected resistance O.L or greater than 1MOhm

Isolate as per TOPs P4
and refit as necessary