Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB
Use insulation mat as required
DHW temperature control to MAX
Ensure boiler is cool so there is a demand for preheat
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With the fan running measure DC voltage at the PCB test pin between the lower white wire at connector J4 on the PCB and a suitable earth point.
Expect approx 6.5V DC.