Set Appliance State:

Gas Off
Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Disconnect green leads from the air pressure switch and make safe
Attach multimeter probe leads to the exposed terminals of the air pressure switch
Ensure there is a demand to heat the thermal store - this can be achieved by running the DHW with power turned off to the appliance
Observe multimeter reading, resistance should be open circuit.
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow combustion fan to run while observing multimeter.
Does the resistance reading change to short circuit?
Mains Power Off.
Replace leads after test.